Daikin Aircon Error Codes: What They Mean and When to Call Repair

How to read a Daikin error code with your remote, what common codes like A5, U0 and U4 mean, and which ones need a technician.
Daikin Aircon Error Codes: What They Mean and When to Call Repair | Wei Wei Aircon
11.16.2026

A Daikin aircon error code is a two-character fault message, such as U4 or A5, that the unit stores when its self-diagnosis detects a problem. On most Daikin wall-mounted units you read it by holding the timer cancel button on the remote for about 5 seconds until “00” flashes, then pressing it repeatedly until you hear a long beep. Codes linked to power or a one-off glitch may clear after a reset, but codes pointing to refrigerant, the compressor, fan motors or circuit boards need a technician.

Daikin is one of the most common brands we see in Singapore homes, from older non-inverter splits to the newer System 2 and System 3 multi-splits, and it often comes up when owners compare brands, as in our Daikin vs Mitsubishi comparison. When the green lamp starts blinking and the room stops cooling, the error code is the fastest way to understand what went wrong. This guide explains how to pull the code, what the common codes mean, and which ones you can handle yourself.

How a Daikin Aircon Tells You Something Is Wrong

Most Daikin wall-mounted indoor units do not show the code directly on the unit. Instead, the operation lamp on the front panel blinks and the unit usually stops cooling. The actual code is stored in the indoor unit’s memory, and you retrieve it through the wireless remote.

Ceiling cassette and ducted Daikin units with a wired controller are different. Many wired controllers display the code on the screen as soon as the fault happens, so you can simply note it down. If your wired controller shows a code, skip straight to the table below.

How to Read the Error Code With Your Daikin Remote

The steps below follow the procedure published on Daikin’s official error code page. Button names vary slightly between remote models, so check the label on yours.

  1. Point the remote at the indoor unit. Stand where you would normally switch the aircon on.
  2. Hold the timer cancel button for about 5 seconds. On remotes with separate ON TIMER and OFF TIMER buttons, use either cancel button. A “00” will flash on the temperature display.
  3. Press the timer cancel button again, one press at a time. Each press shows the next possible code. You will hear a short beep, or two short beeps, for codes that do not match the fault.
  4. Stop when you hear a continuous long beep. The code on the remote screen at that moment is your error code.
  5. Exit the mode. Hold the timer cancel button for 5 seconds again, or leave the remote alone for about 1 minute and the display returns to normal.

Scrolling can take a while, so be patient. If you are unsure which button to use, the remote model number is printed on the back or inside the battery cover, and its manual will show the exact steps.

Common Daikin Aircon Error Codes and What They Mean

The meanings below come from Daikin’s official error code search tool for room air conditioners. Exact causes can vary by model, so treat this as a guide and confirm with a technician before replacing parts.

Code Daikin’s description Who should handle it
A1 Malfunction of indoor unit PCB Technician
A3 Malfunction of drain level control system Technician (often drain related)
A5 High pressure control in heating, freeze-up protection control in cooling Check filter first, then technician
A6 Fan motor locked, overload, overcurrent Technician
C4 Malfunction of liquid pipe thermistor for heat exchanger Technician
C9 Malfunction of suction air thermistor Technician
E5 Overheat of inverter compressor motor Technician
E7 Malfunction of outdoor unit fan motor Technician
E8 Overcurrent of inverter compressor Technician
F3 Malfunction of discharge pipe temperature Technician
H6 Malfunction of position detection sensor Technician
J3 Malfunction of discharge pipe thermistor Technician
L4 Malfunction of inverter radiating fin temperature rise Check outdoor airflow, then technician
L5 Inverter instantaneous overcurrent (DC) Technician
U0 Shortage of refrigerant Technician
U2 Defect of power supply voltage or instantaneous power failure Try a reset first
U4 Malfunction of transmission between indoor and outdoor unit Try a reset first, then technician

What Each Code Series Usually Points To

Daikin groups its codes by letter, and the letter alone already tells you roughly where the problem sits.

A series: indoor unit

A codes relate to the indoor unit: its circuit board, fan motor, drainage and coil protection. A5 is one of the codes we meet most often, because a choked filter or dirty coil can make the indoor coil too cold, which triggers freeze-up protection.

C and J series: sensors

C codes point to indoor thermistors (temperature sensors), while J codes point to outdoor ones. A failed or disconnected sensor feeds the board wrong readings, so the unit shuts down to protect itself. These are usually part replacements rather than cleaning jobs.

E, F, H and L series: outdoor unit and compressor

These codes cover the compressor, outdoor fan, discharge temperature and the inverter electronics. Some are caused by a failing part, but heat stress also plays a role. An outdoor unit squeezed into a tight ledge with poor airflow, or one with a clogged condenser coil, runs hotter and is more likely to trip protection codes.

U series: system and power

U codes cover refrigerant shortage, power supply problems and communication between indoor and outdoor units. U0 means the system believes it is short of refrigerant, which usually means a leak somewhere. U2 and U4 can follow a power trip or voltage dip and sometimes clear after a reset, but if they keep coming back, the wiring or a board needs checking.

Daikin Codes That Regular Aircon Servicing Can Help Prevent

Not every fault is preventable, but a good share of the Daikin codes we see trace back to dirt, blocked drainage or heat build-up. Keeping to a routine of regular aircon servicing removes most of those triggers before they turn into a shutdown.

  • A5 (freeze-up protection). Dusty filters and a coated indoor coil reduce airflow, the coil gets too cold and ice forms. Our guide on why aircon freezes up covers this in detail.
  • A3 (drain level control). On units with a drain level system, sludge in the drain pan and pipe can trigger this code. Flushing the drain line during servicing keeps it clear.
  • A6 (indoor fan motor). A blower wheel caked with dust and mould is heavier and harder to turn, which adds strain on the motor over time.
  • E5, L4 and similar heat-related codes. A dirty outdoor condenser coil or blocked airflow at the ledge makes the compressor and inverter board run hotter.
  • U0 (refrigerant shortage). Servicing does not stop a leak, but a technician checking pressures and pipe joints can spot a slow leak early. Our guide to aircon gas top up explains why topping up without finding the leak is only a short-term fix.

What You Can Safely Try Before Calling a Technician

Some codes come from a temporary glitch, such as a power dip during a thunderstorm. Before booking a visit, these owner checks are safe:

  1. Do a power reset. Switch off the aircon at the isolator switch, wait a few minutes, then switch it back on. This clears many U2 and one-off U4 codes.
  2. Check and clean the filters. If you got an A5, take out the filters and wash them. Let them dry fully before refitting.
  3. Check the outdoor unit. Make sure nothing is blocking the outdoor unit, such as stored items on the ledge, plastic sheets or plants.
  4. Check the remote batteries. Weak batteries can make the remote unreliable when you are trying to read codes.

What you should not do is keep resetting the unit when the same code returns. Repeatedly forcing a unit with a compressor, overcurrent or refrigerant code to restart can turn a repairable fault into a much more expensive one. Also avoid opening the indoor or outdoor casing. There is live electricity inside, and the inverter board can hold a charge even after power is off.

When to Call for Daikin Aircon Repair

Call for professional aircon repair if any of these apply:

  • The same code comes back after a reset.
  • The code is in the E, F, H, J, L or C series.
  • You get U0, which points to a refrigerant problem.
  • You smell burning, hear grinding, or the circuit breaker trips together with the code.
  • Water is leaking from the indoor unit along with an A3 code.

When you call, give the technician the code, the indoor and outdoor model numbers from the nameplate stickers, the unit’s rough age, and what happened before the fault. The cost of fixing a fault depends heavily on which part has failed. Our post on aircon repair cost in Singapore explains the main price drivers, from sensors and fan motors to circuit boards and compressors.

How Wei Wei Aircon Handles Daikin Error Codes

We have been servicing and repairing aircon in Singapore for over three decades, and Daikin units are a large part of our daily work. You can see the range of models we cover on our Daikin aircon servicing and repair page.

When you call with a Daikin error code, we start by asking for the code and model so we can come prepared. On site, we confirm the code, then test the related part directly, for example measuring the thermistor reading, checking fan motor operation or reading refrigerant pressures, rather than replacing parts on the code alone. We explain what we found and give you a clear quote before any repair work starts.

If the code was triggered by dirt, a blocked drain or poor airflow, we will tell you so, and recommend the servicing or cleaning that addresses the cause, not just the symptom.

Frequently Asked Questions

How do I check the error code on my Daikin aircon?

Point the remote at the indoor unit and hold the timer cancel button for about 5 seconds until “00” flashes. Press the button repeatedly until you hear a long continuous beep. The code shown at that moment is the error code.

Why is my Daikin aircon green light blinking?

A blinking operation lamp usually means the unit has detected a fault and stored an error code. Use the remote method to read the code, then check it against the table above. If the lamp keeps blinking after a power reset, book a technician.

What does U4 mean on a Daikin aircon?

Daikin describes U4 as a malfunction of transmission between the indoor and outdoor units. It can follow a power dip and sometimes clears after a reset. If it returns, the cause is often wiring between the units or a circuit board, which needs a technician.

What does A5 mean on a Daikin aircon?

In cooling mode, A5 means the freeze-up protection has activated because the indoor coil got too cold. Dirty filters, a dirty coil or low refrigerant are common causes. Clean the filters first, and if it returns, have the unit serviced and checked.

Can I reset a Daikin error code myself?

Yes. Switch off the isolator, wait a few minutes and switch it back on. This is fine to try once, but if the same code comes back, stop resetting and call a technician, as repeated restarts can strain the compressor and electronics.

Does U0 mean my Daikin needs a gas top up?

U0 means the unit detects a refrigerant shortage. Since refrigerant does not get used up in normal operation, a shortage usually means a leak. The leak should be located and repaired before the system is recharged, otherwise the problem will return.

Book Your Aircon Servicing Today

Enjoy guaranteed workmanship, clear quotes, and expert care from Wei Wei Aircon.

  • Phone: +65 6567 7698
  • Location: 451 Jurong West Street 42, #01-180, Singapore 640451
  • Operating Hours: Mon-Sat: 9:00 AM – 6:00 PM

Send Us a Message

You can schedule an appointment or send us your enquiry by filling up the form, or simply give us a call. 

6567 7698